Type FSL-B-ZAB


Decentralised sill units type FSL-B-ZAB supply the building with conditioned fresh air.

In addition to mechanical ventilation with heat recovery and air filtration equipment is guaranteed with this approach, the heating and cooling of office space.

FSL-B-ZAB
Supply and extract air units:

  • Mechanical ventilation with heat recovery
  • Heat exchanger for heating and cooling
  • Under sill installation
  • Quasi displacement flow
  • Energy efficient radial flow fans
  • Controlled/limited fresh air flow rate independent of wind pressure
  • Low sound power level

FSL-B-ZAB
Legend
1 Volume flow rate controller
2 Backdraught damper
3 Motorised shut-off damper
4 F7 – Outside air filter
5 Supply/exhaust air fan
6 Recuperative heat recovery unit
7 Silencer
8 Air heater
9 Chiller
10 Motorised heat recovery unit bypass damper
11 G3 – Extract air filter

SRO Outside air single room
SRS Supply air single room
SEH Exhaust air single room
SET Extract air single room
Supply and extract air units maintain a high air quality in rooms by supplying conditioned outdoor air to the room. For the discharge of the air, the unit has two radial fans.
The supply air fan takes in outdoor air, which flows through a volume flow limiter, a non-return damper, a shut-off damper and a fine dust filter. These components prevent the exceeding of the dimensioned outdoor air flow through wind pressure, the switching of the flow direction in case of a negative pressure on the façade and uncontrolled flows when the device is turned off. The F7 fine dust filter complies with the hygiene requirements of VDI 6022.
For the thermal conditioning of the outdoor air heat exchangers for heat recovery, heating and cooling are used. The heat recovery takes place recuperatively using a plate heat exchanger. A part of the heat in the extract air is transferred to the outdoor air. In energetically sensible cases, a bypass damper opens the heat recovery bypass during the transitional period and for the prevention of freezing.
Similar to displacement flow, the supply air flows through the floor grille into the room.
The extract air fan takes in the room air near the floor and discharges it outdoor through the heat exchanger for heat recovery, the non-return damper and the shut-off damper. A coarse dust filter in the extract air protects the fan and heat exchanger from dirt.
Static heating operation without ventilation is possible. The integrated thermal switch closes and the unit works like an underfloor unit.
FSL-B-ZAB
Under sill ventilation units type FSL-B-ZUS with supply and exhaust functions are used for decentralised
ventilation and for heating and cooling of rooms and buildings. The devices are manufactured according to
specific project-site conditions. The under sill units consist of a casing of galvanized sheet steel, which axle
is integrated into the façade.
The units are attached to the concrete sill.
Closed-form part of the sealant and seal the device from external and exhaust openings.
The weather protection is provided by the façade.

 

Downloads Group Type Ident-No. Type / Size
         
LAIMER WÜRFEL - Decentralised sill ventilation units FSL-B-ZAB Decentralized Ventilation Systems Project Information PI/FSL/12/EN/2 PDF / 1.7 MB 
Traungasse office building - Decentralised sill ventilation units FLS-B-ZAB / SEK Decentralized Ventilation Systems Project Information PI/FSL/15/EN/1 PDF / 352 KB 

Reference

Distrito de la Comunicación de Telefónica

More than 30,000 TROX chilled beams of DID300B type
Reference

Contact

TROX Malaysia Sdn Bhd.

20 Persiaran Bunga Tanjung 1
Senawang Land Industrial Park
Tel: (+6) 06-678 8188
Contact and locations